Violation Detail
Standard Cited: 19100023 D02 Ladders.
Inspection Nr: 1558308.015
Citation: 01001
Citation Type: Serious
Abatement Date: 02/17/2022 2
Initial Penalty: $4,661.00
Current Penalty: $2,330.50
Issuance Date: 02/11/2022
Nr Instances: 1
Nr Exposed: 2
Related Event Code (REC): R
Gravity: 1
Report ID: 0111700
Contest Date:
Final Order: 02/16/2022
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 02/16/2022 | $2,330.50 | 02/17/2022 | Serious | |
Penalty | Z: Issued | 02/11/2022 | $4,661.00 | 02/17/2022 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.23(d)(2): The employer did not ensure that the minimum perpendicular distance from the centerline of the steps or rungs, or grab bars, or both, to the nearest permanent object in back of the ladder is 7 inches (18 cm): Site - A fixed ladder used to access a work platform was installed with only 4.5 inches of clearance between the centerline of the rungs and the steel structure of which it was attached.