Violation Detail
Standard Cited: 19100147 D The control of hazardous energy (lockout/tagout).
This violation item has been deleted.
Inspection Nr: 1553509.015
Citation: 01001
Citation Type: Serious
Abatement Status:
Initial Penalty: $14,502.00
Current Penalty: $0.00
Issuance Date: 02/18/2022
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 03/17/2022
Gravity: 10
Report ID: 0521700
Contest Date:
Final Order: 03/07/2022
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 03/07/2022 | $0.00 | 03/17/2022 | Serious | |
| Penalty | Z: Issued | 02/18/2022 | $14,502.00 | 03/17/2022 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6): a.) Production Scaling Room - On or about September 3, 2021, employees were exposed to machine hazards associated with moving parts while unclogging the dispensing port on the Savage Bros. Co. Chocolate Melter, Model No. 125 CMT, Serial No. 124. The employer failed to implement energy control application steps as the machine was not shut down or turned off to perform the servicing work [per the 1910.147(d)(2) requirements]. As a result, the remaining applicable energy control elements, involving machine isolation [(d)(3)], LOTO device application [(d)(4)], dissipation of residual energy [(d)(5)((i)], and verification of isolation [(d)(6)], were not implemented to protect employees from machine servicing hazards.
Translate