Violation Detail
Standard Cited: 19100179 F06 III Overhead and gantry cranes.
Inspection Nr: 1549124.015
Citation: 01001
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $14,502.00
Current Penalty: $14,502.00
Issuance Date: 02/04/2022
Nr Instances: 1
Nr Exposed: 5
Abatement Date: 03/03/2022
Gravity: 10
Report ID: 0418300
Contest Date:
Final Order: 03/02/2022
Related Event Code (REC): C
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | Z: Issued | 02/04/2022 | $14,502.00 | 03/03/2022 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.179(f)(6)(iii): All floor, remote and pulpit operated crane bridge drives were not provided with a brake or non-coasting mechanical drive: (a) On or about 8/23/2021 and at times prior - Larger Diameter (LD) Department, employees were exposed to struck-by hazards because the overhead crane used to move large diameter pipe was not equipped with an adequate braking system.
Translate