Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1548677.015
Citation: 01001
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $13,052.00
Current Penalty: $6,751.00
Issuance Date: 01/25/2022
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 03/11/2022
Gravity: 10
Report ID: 0317700
Contest Date:
Final Order: 02/18/2022
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 02/18/2022 | $6,751.00 | 03/11/2022 | Serious | |
| Penalty | Z: Issued | 01/25/2022 | $13,052.00 | 02/11/2022 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) Main Production Floor - On or about August 12, 2021, lockout tagout procedures were not utilized on the Sencorp Thermoformer #17 line, exposing employees to electric shock hazards. ABATEMENT CERTIFICATION AND DOCUMENATION REQUIRED