Violation Detail
Standard Cited: 19100147 C04 II D The control of hazardous energy (lockout/tagout).
Inspection Nr: 1545741.015
Citation: 01001
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $14,502.00
Current Penalty: $7,500.00
Issuance Date: 01/20/2022
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 06/26/2023
Gravity: 10
Report ID: 0627100
Contest Date: 02/03/2022
Final Order: 06/01/2023
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 06/01/2023 | $7,500.00 | 06/26/2023 | Serious | |
Penalty | C: Contested | 02/03/2022 | $14,502.00 | 02/01/2022 | Serious | |
Penalty | Z: Issued | 01/20/2022 | $14,502.00 | 02/01/2022 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(c)(4)(ii)(D): The energy control procedures did not clearly and specifically outline the requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control On or about July 29, 2021, at Planer #1, the employer did not ensure that the lockout and tagout procedure outlined the verification steps for the presence of residual stored energy, exposing employees to caught-in injuries.