Violation Detail
Standard Cited: 19100147 D02 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1541036.015
Citation: 01001
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $5,461.00
Current Penalty: $2,731.00
Issuance Date: 07/16/2021
Nr Instances: 1
Nr Exposed: 2
Abatement Date:
Gravity: 10
Report ID: 0522300
Contest Date:
Final Order: 08/11/2021
Related Event Code (REC): A
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 08/11/2021 | $2,731.00 | Serious | ||
| Penalty | Z: Issued | 07/16/2021 | $5,461.00 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(d)(2):The machine or equipment was not turned off or shut down using the procedures established for the machine or equipment: On or about July 1, 2021 the employer failed to ensure that machine specific procedures for the control of hazardous energies were utilized prior to service and maintenance of the auger system. Employees were engaged in the freeing of the the rotating auger. At the time the blower, vane feeder, and auger were not locked or tagged out in accordance with the procedures.
Translate