Violation Detail
Standard Cited: 19100147 C07 I A The control of hazardous energy (lockout/tagout).
Inspection Nr: 1540180.015
Citation: 01001
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $13,653.00
Current Penalty: $10,239.75
Issuance Date: 12/10/2021
Nr Instances: 1
Nr Exposed: 10
Abatement Date: 02/22/2022
Gravity: 10
Report ID: 0523900
Contest Date:
Final Order: 01/05/2022
Related Event Code (REC): C
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 01/05/2022 | $10,239.75 | 02/22/2022 | Serious | |
Penalty | Z: Issued | 12/10/2021 | $13,653.00 | 01/04/2022 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control: (a) Big mill area; Authorized level lockout training was not provided to each employee before they performed the servicing and/or maintenance activity of rubber jam clearing on shear screw mixing equipment for production line 100.