Standard Cited: 19260651 C02 Specific Excavation Requirements.

Inspection Nr: 1539724.015

Citation: 01001

Citation Type: Serious

Abatement Status: Corrected During Inspection

Initial Penalty: $3,901.00

Current Penalty: $1,950.50

Issuance Date: 10/29/2021

Nr Instances: 1

Nr Exposed: 2

Abatement Date:

Gravity: 5

Report ID: 0521100

Contest Date:

Final Order: 12/22/2021

Related Event Code (REC):

Emphasis:


Penalty and Failure to Abate Event History
Type Latest Event Event Date Penalty Abatement Due Date Citation Type Failure to Abate Inspection
Penalty I: Informal Settlement 12/22/2021 $1,950.50   Serious  
Penalty Z: Issued 10/29/2021 $3,901.00   Serious  

Text For Citation: 01 Item/Group: 001 Hazard:

29 CFR 1926.651(c)(2): Means of egress from trench excavations. A stairway, ladder, ramp or other safe means of egress shall be located in trench excavations that are 4 feet (1.22 m) or more in depth so as to require no more than 25 feet (7.62 m) of lateral travel for employees. On July 1, 2021 at Holland Road and Co Hwy D in Kaukauna, Wisconsin, employees were working from inside a trench excavation at nine and one half feet deep without a safe means of egress. There was no ladder installed for employee use.

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close