Standard Cited: 19100219 C02 I Mechanical power-transmission apparatus.
Inspection Nr: 1536805.015
Citation: 01001
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $5,461.00
Current Penalty: $3,276.60
Issuance Date: 09/20/2021
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 10/19/2021
Gravity: 10
Report ID: 0636900
Contest Date:
Final Order: 10/13/2021
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 10/13/2021 | $3,276.60 | 10/19/2021 | Serious | |
| Penalty | Z: Issued | 09/20/2021 | $5,461.00 | 10/19/2021 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.219(c)(2)(i):All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting. On or about June 9, 2021, and at times prior thereto, the employer did not ensure the feed rollers were guarded on the PBR machine (R-panel former) exposing employees to caught-in and amputation hazards.