Violation Detail
Standard Cited: 19100147 C06 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1534405.015
Citation: 01001
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $13,653.00
Current Penalty: $7,000.00
Issuance Date: 11/15/2021
Nr Instances: 3
Nr Exposed: 3
Abatement Date: 12/10/2021
Gravity: 10
Report ID: 0521700
Contest Date:
Final Order: 12/06/2021
Related Event Code (REC): C
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 12/06/2021 | $7,000.00 | 12/10/2021 | Other | |
Penalty | Z: Issued | 11/15/2021 | $13,653.00 | 12/10/2021 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a.) Production Floor - On or about June 1, 2021, a machine operator performed the service/maintenance task of cleaning the Martin die cutter machine, model 5124, serial no. 455. The employer did not ensure periodic inspections of the energy control procedures were performed at least annually as required by the standard. b.) Production Floor - On or about June 1, 2021, a machine operator performed the service/maintenance task of cleaning the Marumatsu die cutting machine. The employer did not ensure periodic inspections of the energy control procedures were performed at least annually as required by the standard. c.) Production Floor - On or about June 2, 2021, a machine operator performed the service/maintenance task of setting-up the Martin die cutter, model 5124, serial no. 455. The employer did not ensure periodic inspections of the energy control procedures were performed at least annually as required by the standard.