Violation Detail
Standard Cited: 19100219 D01 Mechanical power-transmission apparatus.
Inspection Nr: 1532018.015
Citation: 01001
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $4,973.00
Current Penalty: $3,200.00
Issuance Date: 11/15/2021
Nr Instances: 1
Nr Exposed: 4
Abatement Date: 12/03/2021
Gravity: 1
Report ID: 0336000
Contest Date:
Final Order: 12/02/2021
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 12/02/2021 | $3,200.00 | 12/03/2021 | Serious | |
| Penalty | Z: Issued | 11/15/2021 | $4,973.00 | 12/03/2021 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.219(d)(1):Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): A) Vitro Flat Glass, LLC on or about May 20, 2021 at the address of 5123 Victory Blvd., Cochranton, PA --- Train Shed: Belt/pulley system was not guarded. The belt and pulley system was located 2 feet from the ground.