Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1524961.015
Citation: 01001
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $12,288.00
Current Penalty: $10,000.00
Issuance Date: 10/08/2021
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 10/19/2021
Gravity: 10
Report ID: 0418600
Contest Date:
Final Order: 11/04/2021
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 11/04/2021 | $10,000.00 | 10/19/2021 | Serious | |
Penalty | Z: Issued | 10/08/2021 | $12,288.00 | 10/19/2021 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(c)(4)(i): Procedures were not utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) SC Duct Machine; On or about April 28 2021 and times prior, the employer exposed employees to amputation hazards in that the employer failed to ensure employees utilized the machine specific lockout tagout procedure while engaged in clearing jams which required employees to reach into/near the point-of-operation to pick up the resonator from the heating plate and place it back onto the vacuum area of the top mold before the molds closed onto the heating plate.