Violation Detail
Standard Cited: 19100147 C07 I A The control of hazardous energy (lockout/tagout).
Inspection Nr: 1523368.015
Citation: 01001
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $13,653.00
Current Penalty: $8,192.00
Issuance Date: 08/27/2021
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 02/28/2022
Gravity: 10
Report ID: 0522300
Contest Date:
Final Order: 09/24/2021
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 09/24/2021 | $8,192.00 | 02/28/2022 | Serious | |
Penalty | Z: Issued | 08/27/2021 | $13,653.00 | 09/16/2021 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(c)(7)(i)(A):Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation: On or about April 5, 2021 the employer failed to ensure that employees tasked with servicing and maintaining equipment at the facility had received authorized training in the control of hazardous energies. Employees who perform size changes and setup of the straightener in the QVL department had not received training on the control of hazardous energies. Hazardous energies present on the equipment include but not limited to pneumatic, hydraulic, mechanical, and electrical.