Violation Detail
Standard Cited: 19100219 C02 I Mechanical power-transmission apparatus.
Inspection Nr: 1522334.015
Citation: 01001
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $12,873.00
Current Penalty: $8,207.00
Issuance Date: 08/30/2021
Nr Instances: 1
Nr Exposed: 3
Abatement Date:
Gravity: 5
Report ID: 0523300
Contest Date:
Final Order: 09/23/2021
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 09/23/2021 | $8,207.00 | Serious | ||
| Penalty | Z: Issued | 08/30/2021 | $12,873.00 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
1910.219(c)(2)(i) All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting:(a)(LOCATION)(IDENTIFY SPECIFIC OPERATION(S) AND/OR CONDITIONS)(DESCRIBE HAZARD(S) WHERE NECESSARY)(3)RUNWAYS USED EXCLUSIVELY FOR OILING OR RUNNING ADJUSTMENTS EXCLUDED. 29 CFR 1910.212(a)(1):One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: On or about March 23, 2021 line 1 SAM line rotating end shaft was not guarded to protect employee from rotating parts.