Violation Detail
Standard Cited: 19100147 C04 II D The control of hazardous energy (lockout/tagout).
This violation item has been deleted.
Inspection Nr: 1517355.015
Citation: 01001
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $12,873.00
Current Penalty: $0.00
Issuance Date: 05/17/2021
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 06/04/2021
Gravity: 5
Report ID: 0522000
Contest Date:
Final Order: 06/02/2021
Related Event Code (REC): R
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 06/02/2021 | $0.00 | 06/04/2021 | Serious | |
Penalty | Z: Issued | 05/17/2021 | $12,873.00 | 06/04/2021 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(c)(4)(ii)(D): The procedures shall clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, the following: (D): Specific requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control measures. a) On or before 2/23/2021 the employer did not provide effective energy control procedures that included testing and positioning procedures ensuring that employees understood the procedures for testing and securing energy sources for machinery such as but not limited to Stacker #1.