Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1516094.015
Citation: 01001
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $13,653.00
Current Penalty: $6,750.00
Issuance Date: 04/20/2021
Nr Instances: 3
Nr Exposed: 3
Abatement Date: 05/13/2022
Gravity: 10
Report ID: 0729300
Contest Date: 05/13/2021
Final Order: 04/01/2022
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | J: ALJ Decision | 04/01/2022 | $6,750.00 | 05/13/2022 | Serious | |
Penalty | C: Contested | 05/13/2021 | $13,653.00 | 05/07/2021 | Serious | |
Penalty | Z: Issued | 04/20/2021 | $13,653.00 | 05/07/2021 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in the activities covered by this section. On or about 2/23/2021, The Greenbrier Companies, LLC DBA The Greenbrier Companies, had not developed, documented and utilized procedures for the control of potentially hazardous energy for several machines in the plant to include, but not limited to the following machines: a) Clearing Niagara 230 Ton Press, Model HBM-230-10-12; b) Accurpress 400 Ton Press, Model 740014; c) And, Standard Industrial Corp. 400 Ton Press Brake, Model J0040.