Violation Detail
Standard Cited: 19260502 D06 I Fall protection systems criteria and practices.
Inspection Nr: 1512686.015
Citation: 01001
Citation Type: Serious
Abatement Status: Not Completed - AD Discretion
Initial Penalty: $3,218.00
Current Penalty: $3,218.00
Issuance Date: 02/23/2021
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 03/09/2021
Gravity: 5
Report ID: 0521400
Contest Date:
Final Order: 03/26/2021
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | Z: Issued | 02/23/2021 | $3,218.00 | 03/09/2021 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1926.502(d)(6)(i):A snaphook not of the locking type was engaged (i) directly to webbing, rope or wire rope; (ii) to each other (iii) to a Dee-ring to which another snaphook or other connector is attached;(iv) to a horizontal lifeline; or (v) to any objectwhich is incompatibly shaped or dimensioned in relation to the snaphook such that unintentional disengagement could occur by the connected object being able to depress the snaphook keeper and release itself. On or about February 1, 2021 employees used standard snap hooks directly attached to itself (lanyard webbing), exposing the snaphook to the possibility of an unintentional disengagement, exposing the employees to a fall of over 17 feet. Abatement certification is required of this item in accordance with the requirements of 29 CFR 1903.19(c).