Violation Detail
Standard Cited: 19260501 B01 Duty to have fall protection.
Inspection Nr: 1512050.015
Citation: 01001
Citation Type: Serious
Abatement Status: Not Completed - Worksite Changed
Initial Penalty: $4,096.00
Current Penalty: $2,745.00
Issuance Date: 07/01/2021
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 07/08/2021
Gravity: 10
Report ID: 0524200
Contest Date:
Final Order: 07/30/2021
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 07/30/2021 | $2,745.00 | 07/08/2021 | Serious | |
| Penalty | Z: Issued | 07/01/2021 | $4,096.00 | 07/08/2021 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: a) On or about January 19, 2021, employees engaged in electrical work were not protected from fall hazards while working at an elevation of approximately 18 feet above the ground. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Translate