Standard Cited: 19100147 C04 II The control of hazardous energy (lockout/tagout).
Inspection Nr: 1508867.015
Citation: 01001
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $13,653.00
Current Penalty: $7,099.56
Issuance Date: 06/16/2021
Nr Instances: 1
Nr Exposed: 19
Abatement Date: 07/21/2021
Gravity: 10
Report ID: 0419700
Contest Date:
Final Order: 07/12/2021
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 07/12/2021 | $7,099.56 | 07/21/2021 | Serious | |
Penalty | Z: Issued | 06/16/2021 | $13,653.00 | 07/21/2021 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, including, but not limited to items (a) through (d) of this section: a. On or about January 4, 2021, at the Bindery Department, the employer's Equipment Lockout/Tagout Procedures did not specifically outline the scope, purpose, rules and steps for the control the hazardous energy for equipment with more than one source of hazardous energy and potential to release stored energy, such as but not limited to, the Muller Martini' s Bravo Feeder, Saddle Stitcher and Three Knife Trimmer, the Muller Martini's Zenith Three Knife Trimmer, and ARPAC Shrink Wrapper, among other machinery.