Violation Detail
Standard Cited: 19100242 B Hand and portable powered tools and equipment, general.
Inspection Nr: 1507212.015
Citation: 01001
Citation Type: Serious
Abatement Date: 3
Initial Penalty: $13,653.00
Current Penalty: $6,826.50
Issuance Date: 06/03/2021
Nr Instances: 1
Nr Exposed: 7
Related Event Code (REC): A
Gravity: 10
Report ID: 0419400
Contest Date:
Final Order: 07/09/2021
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 07/09/2021 | $6,826.50 | Serious | ||
Penalty | Z: Issued | 06/03/2021 | $13,653.00 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.242(b): Compressed air used for cleaning. Compressed air shall not be used for cleaning purposes except where reduced to less than 30 p.s.i. and then only with effective chip guarding and personal protective equipment: (a) Knife sharpening room - On or about December 15, 2020 the employer did not ensure air pressure used to dry and clean tools, such as knives, was reduced to less than 30 p.s.i. exposing employees to hazards associated with compressed air, such as air embolism.