Violation Detail
Standard Cited: 19100212 A03 II General requirements for all machines.
Inspection Nr: 1502165.015
Citation: 01001
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $10,533.00
Current Penalty: $6,000.00
Issuance Date: 04/20/2021
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 05/14/2021
Gravity: 5
Report ID: 0336000
Contest Date:
Final Order: 05/11/2021
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 05/11/2021 | $6,000.00 | 05/14/2021 | Serious | |
| Penalty | Z: Issued | 04/20/2021 | $10,533.00 | 05/14/2021 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.212(a)(3)(ii): The point of operation of machines whose operation exposes an employee to injury, was not guarded: a) production floor, on or about November 3, 2020, the point of operation on the Cincinnati hydraulic press brake was inadequately guarded. The Triad Superlight VI light curtain was not operating properly to protect operators from the pinch-point created by the hydraulic press during normal operations. On or about November 3, 2021, an employee experienced amputation injuries to the right hand while operating the press when the light curtain/controller system failed.