Violation Detail
Standard Cited: 19260307 D01 Mechanical power-transmission apparatus.
This violation item has been deleted.
Inspection Nr: 1501844.015
Citation: 01001
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $11,703.00
Current Penalty: $0.00
Issuance Date: 01/29/2021
Nr Instances: 1
Nr Exposed: 2
Abatement Date:
Gravity: 5
Report ID: 0522300
Contest Date:
Final Order: 02/23/2021
Related Event Code (REC): R
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 02/23/2021 | $0.00 | Serious | ||
Penalty | Z: Issued | 01/29/2021 | $11,703.00 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1926.307(d)(1):"Guarding." Pulleys, any parts of which are 7 feet (2.128 m) or less from the floor or working platform, shall be guarded in accordance with the standards specified in paragraphs (m) and (o) of this section. Pulleys serving as balance wheels (e.g., punch presses) on which the point of contact between belt and pulley is more than 6 ft. 6 in. (1.976 m) from the floor or platform may be guarded with a disk covering the spokes. On or about November 5, 2020, during the installation of conveyers for the construction of a distribution center, the employer did not ensure the belt and pulleys of the CP88 inclined and horizontal conveyors' powered take-off drive was guarded. The belt and pulleys of the CP88 conveyors' powered take-off were located approximately 42 inches above the floor.