Violation Detail
Standard Cited: 19100147 D03 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1496480.015
Citation: 01001
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $6,940.00
Current Penalty: $6,940.00
Issuance Date: 12/10/2020
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 01/07/2021
Gravity: 5
Report ID: 0626700
Contest Date:
Final Order: 01/06/2021
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 01/06/2021 | $6,940.00 | 01/07/2021 | Other | |
| Penalty | Z: Issued | 12/10/2020 | $6,940.00 | 01/07/2021 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s): a) On or about October 3, 2020 at the facility where employees were exposed to caught-in hazards when performing service and maintenance tasks such as adjusting a chain on a Hyster forklift without isolating all energy sources.
Translate