Violation Detail
Standard Cited: 19260652 E02 I Requirements for protective systems.
Inspection Nr: 1481576.015
Citation: 01001
Citation Type: Other
Abatement Status: Not Completed - Worksite Changed
Initial Penalty: $6,940.00
Current Penalty: $5,000.00
Issuance Date: 07/28/2020
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 08/03/2020
Gravity:
Report ID: 0627700
Contest Date:
Final Order: 09/18/2020
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 09/18/2020 | $5,000.00 | 08/03/2020 | Other | |
| Penalty | Z: Issued | 07/28/2020 | $6,940.00 | 08/03/2020 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1926.652(e)(2)(i): Excavation of material to a level no greater than 2 feet (.61m) below the bottom of the members of a support system was permitted where the system was not designed to resist the forces calculated for the full depth of the trench: On or about July 1, 2020, at an excavation site located a I-35 Interstate Drive and Rock Creek Road in Norman, Ok, an employee was allowed to work in a trench with the bottom of the trench box elevated more that two feet above the trench floor, exposing employees to crushed-by and struck-by hazards.