Violation Detail
Standard Cited: 19100147 D The control of hazardous energy (lockout/tagout).
This violation item has been deleted.
Inspection Nr: 1480056.015
Citation: 01001
Citation Type: Serious
Abatement Status:
Initial Penalty: $13,494.00
Current Penalty: $0.00
Issuance Date: 09/17/2020
Nr Instances: 1
Nr Exposed: 5
Abatement Date: 11/04/2020
Gravity: 10
Report ID: 0522000
Contest Date:
Final Order: 10/22/2020
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 10/22/2020 | $0.00 | 11/04/2020 | Serious | |
| Penalty | Z: Issued | 09/17/2020 | $13,494.00 | 11/04/2020 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(d): Application of control. The established procedures for the application of energy control (the lockout or tagout procedures) shall cover the following elements and actions and shall be done in the following sequence: (2) turn off and shut down the machine (3) physically locate and operate the energy isolating devices in such a manner as to isolate the machine or equipment from the energy sources. (4) affix lockout or tagout devices to each energy isolating device (5) Following the application of lockout or tagout devices to energy isolating devices, all potentially hazardous stored or residual energy shall be relieved, disconnected, restrained, and otherwise rendered safe. (6) Prior to starting work on machines that have been locked out or tagged out, verify that isolation and deenergizing of the machine or equipment have been accomplished. a) On or about 6/15/2020, located on the garage door line, employees were exposed to machine hazards associated with rotating shafts while performing production operations, including removal of excess glue from LES/Retail Packaging conveyor system. The employer failed to implement energy control application steps as the conveyor was not shut down or turned off to perform the servicing work [per the 1910.147(d)(2) requirements]. As a result, the remaining applicable energy control elements, involving machine isolation [(d)(3)], LOTO device application [(d)(4)], dissipation of residual energy [(d)(5)(i), and verification of isolation [(d)(6)], were not implemented to protect employees from machine hazards.
Translate