Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
This violation item has been deleted.
Inspection Nr: 1479509.015
Citation: 01001
Citation Type: Serious
Abatement Status:
Initial Penalty: $9,446.00
Current Penalty: $0.00
Issuance Date: 09/25/2020
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 11/10/2020
Gravity: 10
Report ID: 0213600
Contest Date:
Final Order: 10/20/2020
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 10/20/2020 | $0.00 | 11/10/2020 | Serious | |
| Penalty | Z: Issued | 09/25/2020 | $9,446.00 | 11/10/2020 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section. a) On or about 06/18/2020, in the production area; Lockout procedures were not utilized when a press operator was clearing scrap metal from under the ram of the 100 ton Niagara Press. He accidentally actuated the press when his left hand was under the ram resulting on four (4) partial finger amputations. ABATEMENT DOCUMENTATION REQUIRED