Violation Detail
Standard Cited: 19260451 B05 II General requirements.
Inspection Nr: 1477385.015
Citation: 01001
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $3,181.00
Current Penalty: $1,591.00
Issuance Date: 06/22/2020
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 08/15/2020
Gravity: 5
Report ID: 0521400
Contest Date:
Final Order: 07/27/2020
Related Event Code (REC): C
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 07/27/2020 | $1,591.00 | 08/15/2020 | Serious | |
Penalty | Z: Issued | 06/22/2020 | $3,181.00 | 07/07/2020 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1926.451(b)(5)(ii): Each platform greater than 10 feet in length shall not extend over its support more than 18 inches (46 cm), unless it is designed and installed so that the cantilevered portion of the platform is able to support employees without tipping, or has guardrails which block employee access to the cantilevered end. On or about June 4, 2020, the ladder jack scaffold platform extended over 18 inches beyond its support. Employees engaged in residential roofing operations were exposed to fall hazards while working on the ladder jack platform. Abatement documentation is required for this item in accordance with 29 CFR 1903.19(d).