Violation Detail
Standard Cited: 19100212 A01 General requirements for all machines.
Inspection Nr: 1471347.015
Citation: 01001
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $13,494.00
Current Penalty: $13,494.00
Issuance Date: 09/24/2020
Nr Instances: 1
Nr Exposed: 4
Abatement Date: 10/16/2020
Gravity: 10
Report ID: 0627100
Contest Date: 10/23/2020
Final Order: 12/10/2021
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | F: Formal Settlement | 12/10/2021 | $13,494.00 | 10/16/2020 | Serious | |
| Penalty | C: Contested | 10/26/2020 | $13,494.00 | 10/16/2020 | Serious | |
| Penalty | Z: Issued | 09/24/2020 | $13,494.00 | 10/16/2020 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: On or about March 27, 2020 and at times prior thereto on the roof of Mill L, employees unclog filters with a metal rod through R-Valve #17 clean-out opening which has one of the metal bar safety guards cut off. This condition exposed employees to amputation hazards from rotating parts in the R-Valve.