Standard Cited: 19100179 L03 I Overhead and gantry cranes.
Inspection Nr: 1468469.015
Citation: 01001
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $134,937.00
Current Penalty: $13,494.00
Issuance Date: 07/16/2020
Nr Instances: 3
Nr Exposed: 15
Abatement Date: 08/11/2020
Gravity: 10
Report ID: 0522300
Contest Date:
Final Order: 08/07/2020
Related Event Code (REC): A
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 08/07/2020 | $13,494.00 | 08/11/2020 | Serious | |
| Penalty | Z: Issued | 07/16/2020 | $134,937.00 | 08/11/2020 | Willful |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.179(l)(3)(i): Unsafe conditions disclosed by the inspection requirements of 29 CFR 1910.179(j) were not corrected as required and/or adjustments and repairs were not done only by designated personnel: a) On or about February 20, 2020, the employer did not ensure that the Caldwell Univac Multi Cup Vacuum Lifter, SN 15-360 504, had a working 9v battery for the alarm system that notified employees when there is a problem with the vacuum suction/pressure used to hold material.