Violation Detail
Standard Cited: 19100147 D03 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1466654.015
Citation: 01001
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $9,446.00
Current Penalty: $4,723.00
Issuance Date: 03/19/2020
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 03/30/2020
Gravity:
Report ID: 0522300
Contest Date:
Final Order: 04/13/2020
Related Event Code (REC): A
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 04/13/2020 | $4,723.00 | 03/30/2020 | Other | |
| Penalty | Z: Issued | 03/19/2020 | $9,446.00 | 03/30/2020 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s): On or about February 17, 2020, the employer did not ensure the electrical energy isolating device (cord and plug) was operated in a manner to isolate the electrical power of a Warring Food Processor machine, while a cold line cook performed service and maintenance (unjamming) operations.