Violation Detail
Standard Cited: 19100147 C06 II The control of hazardous energy (lockout/tagout).
Inspection Nr: 1464993.015
Citation: 01001
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $13,494.00
Current Penalty: $13,494.00
Issuance Date: 08/06/2020
Nr Instances: 1
Nr Exposed: 16
Abatement Date: 04/03/2023
Gravity: 10
Report ID: 0522000
Contest Date: 08/18/2020
Final Order: 01/18/2023
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 01/18/2023 | $13,494.00 | 04/03/2023 | Serious | |
Penalty | C: Contested | 08/18/2020 | $13,494.00 | 09/10/2020 | Serious | |
Penalty | Z: Issued | 08/06/2020 | $13,494.00 | 09/10/2020 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(c)(6)(ii): The employer shall certify that the periodic inspections have been performed. The certification shall identify the machine or equipment on which the energy control procedure was being utilized, the date of the inspection, the employees included in the inspection, and the person performing the inspection. a) On or about February 14, 2020, located in the Sanitation Department, the employer did not certify that periodic inspections had been conducted for the energy control procedures for machines and equipment, i.e. Line 7 Spiral Infeed Conveyors, thereby exposing employees to a caught-in hazard.