Violation Detail
Standard Cited: 19100147 C06 I B The control of hazardous energy (lockout/tagout).
Inspection Nr: 1463600.015
Citation: 01001
Citation Type: Serious
Abatement Date: 3
Initial Penalty: $9,831.00
Current Penalty: $6,882.50
Issuance Date: 04/02/2020
Nr Instances: 1
Nr Exposed: 9
Related Event Code (REC): A;R
Gravity: 5
Report ID: 0523300
Contest Date: 04/27/2020
Final Order: 11/09/2020
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 11/09/2020 | $6,882.50 | Serious | ||
Penalty | C: Contested | 04/27/2020 | $9,831.00 | Serious | ||
Penalty | Z: Issued | 04/02/2020 | $9,831.00 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(c)(6)(i)(B) The periodic inspection shall be conducted to correct any deviations or inadequacies identified. On or about February 10, 2020, lockout/tagout procedures for the Bond Robotics destacker (Asset No. 6307) were not utilized for the control of the hazardous energy sources when employees entered the operating envelope of the machine to adjust the Syron sensor.