Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1463392.015
Citation: 01001
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $13,494.00
Current Penalty: $0.00
Issuance Date: 03/30/2020
Nr Instances: 3
Nr Exposed: 10
Abatement Date: 04/17/2020
Gravity:
Report ID: 0522300
Contest Date:
Final Order: 04/27/2020
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 04/27/2020 | $0.00 | 04/17/2020 | Other | |
| Penalty | Z: Issued | 03/30/2020 | $13,494.00 | 04/17/2020 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: On or about February 12, 2020, the employer failed to fully develop and implement a program to address the various hazardous energy sources associated with machines, to include but not limited to, the Trumpf Press Brake (serial#50504A0465). The employers program did not identify the machines hydraulic energy sources.
Translate