Violation Detail
Standard Cited: 19100147 D03 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1456790.015
Citation: 01001
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $13,494.00
Current Penalty: $13,494.00
Issuance Date: 01/21/2020
Nr Instances: 1
Nr Exposed: 4
Abatement Date:
Gravity: 10
Report ID: 0522300
Contest Date:
Final Order: 02/19/2020
Related Event Code (REC): A
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | Z: Issued | 01/21/2020 | $13,494.00 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s): On or about January 15, 2020 the employer failed to ensure that employees performing service or maintenance on the R560 vacuum packaging line operated the controls in a manner which isolated the unit from hazardous energies. Hazardous energies present on the equipment include, mechanical, electrical, pneumatic, thermal, and vacuum.