Violation Detail
Standard Cited: 19100029 B02 I Fall protection systems and falling object protection-criteria and practices.
Inspection Nr: 1454598.015
Citation: 01001
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $9,639.00
Current Penalty: $6,000.00
Issuance Date: 04/21/2020
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 05/01/2020
Gravity:
Report ID: 0627500
Contest Date:
Final Order: 05/21/2020
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 05/21/2020 | $6,000.00 | 05/01/2020 | Other | |
| Penalty | Z: Issued | 04/21/2020 | $9,639.00 | 05/01/2020 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.29(b)(2)(i): (i) Midrails were not installed at a height midway between the top edge of the guardrail system and the walking-working surface: On or about January 7, 2020, midrails were not installed at a height midway between the top edge of the guardrail system of the tank battery. This condition exposed employee to falls hazards.