Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
This violation item has been deleted.
Inspection Nr: 1454000.015
Citation: 01001
Citation Type: Serious
Abatement Status:
Initial Penalty: $13,494.00
Current Penalty: $0.00
Issuance Date: 06/22/2020
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 07/17/2020
Gravity: 10
Report ID: 0418300
Contest Date: 07/16/2020
Final Order: 06/03/2021
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | F: Formal Settlement | 06/03/2021 | $0.00 | 07/17/2020 | Serious | |
| Penalty | C: Contested | 07/21/2020 | $13,494.00 | 07/17/2020 | Serious | |
| Penalty | Z: Issued | 06/22/2020 | $13,494.00 | 07/17/2020 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: (a) On or about 12/23/2019 - Chill-Pack, Shipping Dock, Warehouse building, LANGLEY, Vertical Reciprocating Conveyor (VRC), procedures were not utilized for employees cleaning under the conveyor, exposing employees to crushed-by hazards.
Translate