Violation Detail
Standard Cited: 19100147 F01 V The control of hazardous energy (lockout/tagout).
This violation item has been deleted.
Inspection Nr: 1451161.015
Citation: 01001
Citation Type: Serious
Abatement Status:
Initial Penalty: $13,494.00
Current Penalty: $0.00
Issuance Date: 03/31/2020
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 04/06/2020
Gravity: 10
Report ID: 0627500
Contest Date: 04/21/2020
Final Order: 07/06/2020
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 07/06/2020 | $0.00 | 04/06/2020 | Serious | |
Penalty | C: Contested | 04/28/2020 | $13,494.00 | 04/06/2020 | Serious | |
Penalty | Z: Issued | 03/31/2020 | $13,494.00 | 04/06/2020 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(f)(1)(v): Deenergize all systems and reapply energy control measures to continue the servicing and/or maintenance. On or about December 10, 2019, the employer did not ensure that the small packages conveyor leading to the semi-auto loading table was deenergized when replacing/aligning the drive bands. This condition exposed the employee to caught-between hazards.