Violation Detail
Standard Cited: 19100147 D02 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1447361.015
Citation: 01001
Citation Type: Serious
Abatement Date: 05/26/2020 2
Initial Penalty: $13,494.00
Current Penalty: $7,500.00
Issuance Date: 04/08/2020
Nr Instances: 1
Nr Exposed: 3
Related Event Code (REC): R
Gravity: 10
Report ID: 0134000
Contest Date: 05/01/2020
Final Order: 05/12/2020
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 05/12/2020 | $7,500.00 | 05/26/2020 | Serious | |
Penalty | C: Contested | 05/12/2020 | $13,494.00 | 05/26/2020 | Serious | |
Penalty | Z: Issued | 04/08/2020 | $13,494.00 | 05/26/2020 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(d)(2): The machine or equipment was not turned off or shut down using the procedures established for the machine or equipment: Location - metal stacker On or about October 17, 2019, the metal stacker had not been de-energized, resulting in finger amputation to an employee.