Violation Detail
Standard Cited: 19100147 C04 II D The control of hazardous energy (lockout/tagout).
Inspection Nr: 1446645.015
Citation: 01001
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $6,940.00
Current Penalty: $4,842.00
Issuance Date: 04/13/2020
Nr Instances: 1
Nr Exposed: 20
Abatement Date: 05/29/2020
Gravity: 5
Report ID: 0420600
Contest Date:
Final Order: 05/07/2020
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 05/07/2020 | $4,842.00 | 05/29/2020 | Serious | |
| Penalty | Z: Issued | 04/13/2020 | $6,940.00 | 05/29/2020 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(c)(4)(ii)(D): The energy control procedures did not clearly and specifically outline the requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control a) On or about November 19, 2019, at the mail room department, the Lockout/tagout Procedures for machines such as QUIPP Series 350 Stacker, did not clearly and specifically outlined the steps for testing a machine to determine and verify the effectiveness of the lockout / tagout devices, exposing employees to caught-in, pneumatic and electrical hazards.