Violation Detail
Standard Cited: 19100219 D01 Mechanical power-transmission apparatus.
Inspection Nr: 1445545.015
Citation: 01001
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $12,934.00
Current Penalty: $9,053.80
Issuance Date: 12/23/2019
Nr Instances: 6
Nr Exposed: 30
Abatement Date: 01/21/2020
Gravity:
Report ID: 0729300
Contest Date:
Final Order: 01/09/2020
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 01/09/2020 | $9,053.80 | 01/21/2020 | Other | |
| Penalty | Z: Issued | 12/23/2019 | $12,934.00 | 01/21/2020 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): At the time of the inspection, six vertical knitting machines had overhead belts and pulleys less than seven feet above the floor without guards to prevent exposure to rotating belts and pulley pinch points. Abatement certification and abatement documentation is required for this violation. The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful. The abatement certification sheet is enclosed with the citations.