Violation Detail
Standard Cited: 19100212 A03 II General requirements for all machines.
Inspection Nr: 1443671.015
Citation: 01001
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $11,934.00
Current Penalty: $7,160.40
Issuance Date: 01/10/2020
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 02/06/2020
Gravity: 10
Report ID: 0418800
Contest Date:
Final Order: 02/05/2020
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 02/05/2020 | $7,160.40 | 02/06/2020 | Serious | |
| Penalty | Z: Issued | 01/10/2020 | $11,934.00 | 02/06/2020 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.212(a)(3)(ii): Point of operation guards were not designed and constructed as to prevent the operator from having any part of their body in the danger zone during the operating cycle: On or about November 7 2019, at 975 S Congress Ave., Delray Beach, FL, 33445, an employee was exposed to an amputation hazard while operating a drill press that was not equipped with a protective cover at the point of operation.