Violation Detail
Standard Cited: 19100212 A03 II General requirements for all machines.
Inspection Nr: 1443179.015
Citation: 01001
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $6,630.00
Current Penalty: $6,630.00
Issuance Date: 11/20/2019
Nr Instances: 1
Nr Exposed: 1
Abatement Date:
Gravity: 5
Report ID: 0419400
Contest Date:
Final Order: 12/18/2019
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | Z: Issued | 11/20/2019 | $6,630.00 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded or guards were not designed and constructed to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s) (a) At the engineering lab - On or about October 30, 2019 the air leak test did not have guards installed when a leak test was performed exposing employee to amputation hazards.
Translate