Violation Detail
Standard Cited: 19100212 A03 II General requirements for all machines.
Inspection Nr: 1438677.015
Citation: 01001
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $13,260.00
Current Penalty: $8,200.00
Issuance Date: 11/21/2019
Nr Instances: 2
Nr Exposed: 6
Abatement Date: 12/23/2019
Gravity: 10
Report ID: 0213600
Contest Date:
Final Order: 12/04/2019
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 12/04/2019 | $8,200.00 | 12/23/2019 | Serious | |
| Penalty | Z: Issued | 11/21/2019 | $13,260.00 | 12/23/2019 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.212(a)(3)(ii): Point of operation guards were not designed and constructed as to prevent the operator from having any part of their body in the danger zone during the operating cycle: a) On or about 10/21/19 on the 36" Roan flexible packaging machine; an employee, making an adjusting to the web during processing, was exposed to an in-going nip point when the gap on the inlet side of the guard on the draw rollers was measured at 3/4". b) On or about 10/21/19 on the 48" flexible packaging machine; employees were exposed to an in-going nip point hazard when the gap on the inlet side of the guard on the draw rollers was measured at 1/2". ABATEMENT DOCUMENTATION REQUIRED