Violation Detail
Standard Cited: 19100212 A03 II General requirements for all machines.
Inspection Nr: 1435961.015
Citation: 01001
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $13,260.00
Current Penalty: $13,260.00
Issuance Date: 01/14/2020
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 03/05/2020
Gravity: 10
Report ID: 0521400
Contest Date:
Final Order: 02/11/2020
Related Event Code (REC): A;R
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | Z: Issued | 01/14/2020 | $13,260.00 | 03/05/2020 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded or guards were not designed and constructed to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s) On or about September 10, 2019, a temporary employee received a right index finger amputation while operating a Micron America MC-20 Pneumatic Attaching Machine (Grommet Machine). The employer did not ensure adequate guarding was installed to eliminate amputation hazards at the point of operation. Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).