Violation Detail
Standard Cited: 19260451 B05 II General requirements.
Inspection Nr: 1421673.015
Citation: 01001
Citation Type: Serious
Abatement Date: 3
Initial Penalty: $4,048.00
Current Penalty: $4,048.00
Issuance Date: 01/30/2020
Nr Instances: 2
Nr Exposed: 3
Related Event Code (REC): I
Gravity: 10
Report ID: 0214500
Contest Date: 08/28/2020
Final Order: 08/12/2021
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | J: ALJ Decision | 08/12/2021 | $4,048.00 | Serious | ||
Penalty | C: Contested | 09/01/2020 | $4,048.00 | Serious | ||
Penalty | Z: Issued | 01/30/2020 | $4,048.00 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1926.451(b)(5)(ii): The end of a platform greater than 10 feet in length extended over its support more than 18 inches and the platform was not designed and installed so that the cantilevered portion of the platform is able to support employees without tipping, or has guardrails which block employee access to the cantilevered end. a) Building Exterior: Employees were exposed to a 22 foot fall hazard while engaged in roofing activities from a ladder jack scaffold that was 24 feet long.. The end of the platform was not designed and installed so that the cantilevered portion of the platform was able to support employees without tipping, the ladder jack scaffold had an 8 foot overhang over the support, on or about 8/8/2019.