Violation Detail
Standard Cited: 19260405 G02 IV Wiring methods, components, and equipment for general use.
Inspection Nr: 1402361.015
Citation: 01001
Citation Type: Serious
Abatement Date: 12/31/2019 5
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 11/14/2019
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC):
Gravity: 5
Report ID: 0419400
Contest Date:
Final Order:
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | Z: Issued | 11/14/2019 | $0.00 | 12/31/2019 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws: (a) Winch trailer - On or about May 16, 2019 the winch being used to lift tools and equipment to employees working on the tower did not have strain relief on the main power cord and hoist controls, exposing employees to electrical hazards.