Violation Detail
Standard Cited: 19100147 D02 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1400277.015
Citation: 01001
Citation Type: Serious
Abatement Date: 09/30/2019 2
Initial Penalty: $5,304.00
Current Penalty: $3,900.00
Issuance Date: 06/20/2019
Nr Instances: 1
Nr Exposed: 2
Related Event Code (REC): A
Gravity: 10
Report ID: 0522300
Contest Date:
Final Order: 07/18/2019
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 07/18/2019 | $3,900.00 | 09/30/2019 | Serious | |
Penalty | Z: Issued | 06/20/2019 | $5,304.00 | 07/17/2019 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(d)(2): The machine or equipment was not turned off or shut down using the procedures established for the machine or equipment: On or about May 13, 2019, the employer did not ensure employees performing setup operations to include the removal of metal chips, shut down a 60" Webster-Bennett Vertical Lathe Boring Mill (Serial No. 5890-1) known as machine A-5.The company has established energy control procedures for the machine and energy sources include, but not limited to, electric and pneumatic energy sources.