Violation Detail
Standard Cited: 19100212 A03 II General requirements for all machines.
Inspection Nr: 1395515.015
Citation: 01001
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $7,246.00
Current Penalty: $4,500.00
Issuance Date: 07/08/2019
Nr Instances: 1
Nr Exposed: 21
Abatement Date: 08/01/2019
Gravity: 5
Report ID: 0830100
Contest Date:
Final Order: 07/16/2019
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 07/16/2019 | $4,500.00 | 08/01/2019 | Serious | |
| Penalty | Z: Issued | 07/08/2019 | $7,246.00 | 08/01/2019 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.212(a)(3)(ii): Points of operation of machinery were not guarded to prevent employees from having any part of their body in the danger zones during operating cycles: a) Rocky Mountain Twist, Ronan MT: On or about April 23, 2019, and at times prior, employees were exposed to amputation hazards while operating an unguarded Somark International Hot Stamp Machine (M215-003-0002).
Translate