Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1391151.015
Citation: 01001
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $3,978.00
Current Penalty: $2,350.00
Issuance Date: 06/10/2019
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 06/20/2019
Gravity: 10
Report ID: 0521700
Contest Date:
Final Order: 07/02/2019
Related Event Code (REC): R
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 07/02/2019 | $2,350.00 | 06/20/2019 | Serious | |
Penalty | Z: Issued | 06/10/2019 | $3,978.00 | 06/20/2019 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) On or about March 28, 2019, in east end of the shop, the employer failed to ensure an energy control procedure was developed and documented for the control of hazardous energy when an employee was engaged in a service and/or maintenance task, such as using compressed air to clean wood dust from an Oliver 170 Stratoplane Planer Machine, Serial Number 202850.