Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1385390.015
Citation: 01001
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $9,472.00
Current Penalty: $5,475.00
Issuance Date: 06/14/2019
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 07/09/2019
Gravity: 5
Report ID: 0213600
Contest Date:
Final Order: 06/25/2019
Related Event Code (REC): A;R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 06/25/2019 | $5,475.00 | 07/09/2019 | Serious | |
| Penalty | Z: Issued | 06/14/2019 | $9,472.00 | 07/09/2019 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) On or about 03/12/2019 in the CSF room; where energy control procedures did not identify/document the rotational (kinetic) energy of the machine (Tablet Press MF-13) b) On or about 03/12/2019 in the CSF room; where energy control procedures (lockout) were not utilized for daily, end of shift cleaning of Tablet Press MF-13. ABATEMENT CERTIFICATION REQUIRED
Translate